XStore
EC-M12 · NB-IoT / LTE-M / Optional LoRaWAN

Battery-Powered Cellular IoT Data Logger

Industrial IP67 data logger for long-term remote monitoring. Choose 4-20mA, RS-485, digital, mixed analog/digital, or strain-gauge I/O with NB-IoT, LTE-M, and optional LoRaWAN connectivity.

IP67 38,000 mAh STM32L072 SIM7070
Multi-Year Deployment
Industrial Sensor Inputs
Local microSD Backup
Your Cloud / Server
NORVI EC-M12 battery-powered cellular IoT data logger
Why NORVI

Why Choose the NORVI EC-M12

Six reasons integrators and OEMs specify the EC-M12 for unattended field deployments.

Rugged Industrial Design

IP67-rated enclosure built to survive outdoor, agricultural, and industrial environments where standard electronics fail.

Long Battery Life

A 38,000mAh dual-cell Li/SOCl2 battery pack is engineered for multi-year unattended field deployment.

Secure Connectivity

NB-IoT, LTE-M, and 2G fallback via the SIM7070 modem, with optional LoRaWAN for long-range low-power sites.

Cloud Ready

Connect to your own server or platform - NORVI supplies firmware built for your infrastructure, not a locked ecosystem.

Easy Deployment

Programmable I/O, an inbuilt real-time clock, and microSD logging mean fast commissioning in the field.

Reliable Operation

An ultra-low-power STM32L072 MCU and industrial-grade components are designed for years of continuous, unattended service.

Product Lineup

Choose the Right EC-M12 Configuration

One low-power cellular data logger platform with five sensor-interface configurations.

NORVI EC-M12-BC-C6-C-A 4-20mA data logger
Model A EC-M12-BC-C6-C-A
Best for Level, pressure and 4-20mA transmitters

Dual 4-20mA analog input configuration for common industrial process sensors.

  • 2× 4-20mA analog inputs
  • 12V sensor excitation
I/O: 2× 4-20mA Analog
NORVI EC-M12-BC-C6-C-B RS-485 Modbus data logger
Model B EC-M12-BC-C6-C-B
Best for RS-485 and Modbus RTU instruments

Serial interface configuration for third-party industrial sensors and field instruments.

  • 1× RS-485 interface
  • 12V sensor excitation
I/O: 1× RS-485
NORVI EC-M12-BC-C6-C-C digital input data logger
Model C EC-M12-BC-C6-C-C
Best for Pulse, switch and digital sensors

Dual digital input configuration for pulse counting, flow meters and switch-based monitoring.

  • 2× digital inputs
  • 12V sensor excitation
I/O: 2× Digital
NORVI EC-M12-BC-C6-C-D mixed analog and digital data logger
Model D EC-M12-BC-C6-C-D
Best for Mixed analog and digital installations

Flexible mixed-I/O configuration for installations that combine discrete and analog field signals.

  • 1× digital input
  • 2× 4-20mA / 0-10V analog inputs
  • 12V sensor excitation
I/O: 1× Digital + 2× Analog
NORVI EC-M12 strain gauge data logger
Model E EC-M12 Strain Gauge
Best for Load cells, force and weight measurement

Strain-gauge input configuration for precision load and force measurement applications.

  • 1× strain-gauge input
  • 5V / 10V excitation options
I/O: 1× Strain Gauge
Documentation Coming Soon
White-label options available Bulk order support Firmware for your own platform
Engineering Data

Platform Technical Specifications

Common hardware, connectivity and power specifications across the EC-M12 platform.

CategorySpecificationDetails
MicrocontrollerSTM32L072Ultra-low-power MCU
Cellular ModemSIM70702G, Cat-M1 and Cat-NB1 support
Network Support2G / LTE-M / NB-IoTLow-power wide-area cellular connectivity
Optional ConnectivityLoRaWANOptional long-range low-power wireless connectivity
Real-Time ClockInbuiltTimestamping for logged measurements
StoragemicroSD up to 256GBExpandable local data backup
Battery2 × ER34615H Li/SOCl2Non-rechargeable lithium cells
Battery Capacity38,000 mAhCombined dual-cell capacity
EnclosureIP67Dust and water resistant field enclosure
Expected Service Life5+ yearsUnder suitable low-duty-cycle logging profiles
Model Comparison

I/O by Configuration

Compare the sensor interface available on each EC-M12 model before selecting a configuration.

Model4-20mA / 0-10VDigitalRS-485Strain GaugeSensor Power
Model A2× 4-20mA---12V
Model B---12V
Model C---12V
Model D2× 4-20mA / 0-10V--12V
Model E---5V / 10V
Inside the EC-M12

Built for Long-Term, Unattended Field Monitoring

NORVI EC-M12 internal battery pack and PCB view
Battery Management

Multi-Year Runtime, Built In

Dual ER34615H Li/SOCl2 cells provide a combined 38,000mAh capacity for long-duration field deployments with low-duty-cycle operation.

NORVI EC-M12 SIM7070 cellular modem
Cellular Communication

NB-IoT, LTE-M and Optional LoRaWAN

The onboard SIM7070 supports 2G, Cat-M1 and Cat-NB1 networks, with optional LoRaWAN connectivity for suitable long-range low-power deployments.

M8 connector for NORVI EC-M12 sensor wiring
Industrial Inputs

Connect the Sensors Already Used in the Field

Choose 4-20mA analog, RS-485, digital, mixed analog/digital or strain-gauge I/O to match the instrumentation used by the application.

NORVI EC-M12 pole-mounted IP67 enclosure
Rugged Housing

IP67, Field-Ready Enclosure

The IP67-rated enclosure protects the electronics from dust and water in outdoor, agricultural and industrial installations.

NORVI EC-M12 microSD storage and real-time clock
Low-Power Data Logging

Timestamped Measurements with Local Backup

The ultra-low-power STM32L072 architecture, inbuilt real-time clock and microSD storage up to 256GB support scheduled measurements and local backup between transmissions.

NORVI EC-M12 connected to a customer cloud dashboard
Remote Monitoring

Send Data to Your Own Platform

Use cellular or LoRaWAN connectivity to move field readings into your server or cloud platform without requiring routine manual data downloads.

Protocols & Interfaces

Connectivity Options

A compact view of the confirmed communication methods and sensor interfaces available across the EC-M12 platform.

NB-IoT / LTE-M
Low-power cellular connectivity through the SIM7070 modem
Optional LoRaWAN
Long-range low-power wireless option for suitable deployments
MQTT
Documented for transmitting logger data to remote platforms
RS-485 / Modbus RTU
Industrial serial communication available on Model B
Industrial Sensor I/O
4-20mA, 0-10V, digital and strain-gauge options by model
Your Cloud / Server
Firmware can be built around your own remote platform
Where It's Deployed

Remote Monitoring Applications

Use the EC-M12 where power and network access are limited but reliable field measurements still need to reach a remote platform.

Water & Wastewater Monitoring

Monitor level, pressure, flow and other field measurements across reservoirs, tanks, sewer assets and remote wastewater infrastructure.

Explore the Water & Wastewater Monitoring System

Borehole & Groundwater Monitoring

Collect groundwater-level measurements from remote boreholes where mains power and wired communications may not be available.

View Borehole Groundwater Monitoring

Reservoir & Tank Level Logging

Capture level readings from remote reservoirs and tanks and transmit them without routine site visits.

Read the Reservoir Monitoring Case Study

Agricultural Data Logging

Connect field sensors for remote soil, water and environmental measurements across agricultural sites.

Explore Custom Monitoring Projects

Pressure Data Acquisition

Use Model A with industrial 4-20mA pressure transmitters for pipelines, tanks and distributed process monitoring.

View Model A Datasheet

Environmental Monitoring

Log remote environmental measurements with local storage and scheduled low-power transmission to a remote platform.

Browse EC-M12 Documentation
Featured Solution

Building a Complete Water or Wastewater Monitoring System?

See how remote data loggers, industrial sensors and cellular connectivity can be combined for distributed water and wastewater monitoring.

View Water & Wastewater Solution
Power Architecture

Engineered for Years, Not Months

A sleep-first cycle, powered by a 38,000mAh dual-cell pack, is what makes multi-year deployment possible.

Sleep
Wake
Read Sensors
Store Data
Transmit
↩ back to Sleep

The EC-M12 is built around an ultra-low-power STM32L072 microcontroller that spends most of its life in sleep mode. It wakes on a schedule, takes a sensor reading, stores it with a real-time-clock timestamp, transmits over NB-IoT, LTE-M, or LoRaWAN, and returns to sleep - a cycle powered by a 38,000mAh dual-cell Li/SOCl2 battery pack designed for 5+ years of service.

Battery-life note: Actual service life varies with sampling frequency, transmission interval, cellular signal quality, sensor power demand and operating temperature.

Reference Design

System Architecture

A typical remote-monitoring path from field sensor to the customer's dashboard.

Field Sensors4-20mA · RS-485 · Digital · Strain Gauge
NORVI EC-M12STM32L072 · SIM7070 · Local Logging
Wireless NetworkNB-IoT · LTE-M · Optional LoRaWAN
Cloud / ServerYour Own Platform
DashboardRemote Data Visibility
Engineering Resources

Documentation & Downloads

Go directly to the document type needed for design, integration or commissioning.

User Guides

Complete EC-M12 Library

Browse all currently published EC-M12 technical documents and application guides in one place.

View All EC-M12 Documentation
Configuration Support

Not Sure Which EC-M12 Configuration You Need?

Send us your sensor type, interface, reporting interval and connectivity requirement. NORVI can help identify the appropriate EC-M12 configuration for the application.

FAQs

Common Questions

Can't find what you're looking for? Our team is available for a free technical consultation.

It is an industrial IP67 battery-powered programmable IoT data logger with NB-IoT, LTE-M and optional LoRaWAN connectivity for long-term remote monitoring.

The SIM7070 modem supports 2G, Cat-M1 (LTE-M) and Cat-NB1 (NB-IoT) networks.

Yes. LoRaWAN is available as an optional long-range wireless connectivity option alongside cellular connectivity.

The EC-M12 uses a 38,000mAh battery pack built from two ER34615H Li/SOCl2 cells. A 5+ year service life is achievable under suitable low-duty-cycle logging profiles. Actual life depends on sampling frequency, transmission interval, network conditions, sensor load and operating temperature.

Inputs vary by model: dual 4-20mA analog, RS-485, dual digital, mixed digital plus 4-20mA / 0-10V analog, or strain-gauge input with excitation.

Model A is for 4-20mA sensors, Model B for RS-485 / Modbus instruments, Model C for digital or pulse inputs, Model D for mixed digital and analog signals, and Model E for strain-gauge or load-cell applications.

The EC-M12 has an IP67 enclosure rating for outdoor and industrial field deployment.

Yes. Model B provides RS-485, and NORVI application guides document Modbus RTU communication and transmitting Modbus data over MQTT.

Yes. The platform can be integrated with your own server or cloud environment rather than requiring a locked third-party cloud.

Start with the sensor interface: 4-20mA, RS-485, digital, mixed analog/digital or strain gauge. Use the model comparison table above, or send NORVI your sensor type, reporting interval and communication requirements for assistance.

Get Started

Ready to Deploy Your Remote Monitoring Solution?

Talk to NORVI's engineering team about your application, or request a formal quote for your EC-M12 configuration.

NORVI EC-M12 · Battery-Powered Cellular Data Logger